Pellet stoves rely on motors, sensors and a vent that has to stay sealed, since the exhaust is pushed out under pressure. When one stops, we read the error, test the parts with a meter, and look at the vent joints and their distance from framing. Parts come from the maker for your model so the listing stays valid. If a unit is beyond sensible repair, the note says that plainly.

Error codes read before any part is touched
Motors, igniter and switches metered
Vent joints checked for seal under pressure
Distance from vent pipe to framing measured
Maker's parts fitted for your model

How a Pellet Stove Fails and What We Test

Inside its steel case a pellet stove runs as a chain. Pellets drop from the hopper onto a turning screw that meters them into the fire pot. An igniter heats the first load until it catches. One fan forces air through the fire and pushes exhaust out the vent, while another moves warm air into the room. A control board watches temperature and pressure switches and stops everything if a reading looks wrong. When one link fails, the board shuts the stove down, so the symptom you see is often far from the cause. A stove that will not start may have a burned out igniter, but it may also have a vacuum switch that never sees draft because the vent is choked with fly ash. We test the motor, igniter, fans and switches with a meter against the maker's figures, and we clean the fire pot and passages first, because ash buildup imitates almost every part failure.

Pellet venting has its own rules. The pipe has to be the type listed for pellet appliances, joined and sealed so a pressurized exhaust cannot leak into the room, and the termination has to sit a set distance from windows, doors, air intakes and the ground. Some stoves need an outside air kit, especially in tight rooms or mobile homes. The stove itself needs the clearances shown on its label to walls and furniture, and a noncombustible floor pad under and in front of it. When we see a stove in Pico Rivera that was moved, reinstalled or added by a previous owner, venting and clearances are the first things we check, because an inspector will look at them before anything else. If the vent is wrong, fixing the motor alone leaves you with a stove that may run but still fails the rules.

Parts, Pricing and the Visit

Pellet stove parts are model specific, and the listing that let the stove be sold assumes those parts stay in it. So the repair starts with the plate on the back or side of the stove, which gives the maker, model and serial number. With that, we can source the part the manual lists. When a stove is old enough that parts are scarce, we tell you what is available and whether keeping it running still makes sense. A repair price depends on the part and how much of the stove has to come apart, and it is given in writing once the fault is confirmed and before anything is ordered. On the contact page, a line about how the stove behaves before it quits and when it was last cleaned out helps us bring the likely parts. It saves time on the visit.

On the day we bring the tools to clean the whole stove as well as fix it, because a pellet stove that is repaired but left full of ash will stop again within weeks. The fire pot is scraped, the heat passages and the exhaust fan housing are cleared, and the vent is brushed from the stove to the outside cap. Gaskets on the door and the ash pan are checked, since a leaking door upsets the air balance the control board depends on. Once the new part is in, the stove runs through a full start and a period at temperature while we watch the flame and the readings. The note left behind lists the fault, the part and the cleaning done. Owners in Whittier and Bellflower who burn pellets through the winter often book a cleaning visit each autumn so the stove starts the season clean.

How Lorimer Chimney Works Works

Rule Named

Each finding lists the standard or manual behind it

Permits Flagged

The quote says whether the city wants one

Price on Paper

Scope and cost written down before work

Closing Photos

The record finishes with the work shown done

Related Work

Chimney Sweep

Cleaning to the NFPA 211 trigger: once buildup could feed a fire it comes out, and your note records how much there was.

Open →

Chimney Inspection

NFPA 211 sets three inspection depths. We book the shallowest one that answers your question.

Open →

Chimney Repair

Repairs scoped against what a working chimney must have: a sound flue, tight joints, a cap and proper distance from wood.

Open →

Fireplace Inspection

A look at the parts inside the room: firebox, damper, hearth extension and the distance from the opening to mantel and trim.

Open →

Fireplace Repair

Fixes for the items inspectors write up most: cracked firebox walls, short hearths, a damper that will not seal, trim set too close.

Open →

Chimney Level 2 Inspection

A sale, a quake, a chimney fire or a new appliance each call for this deeper level under NFPA 211. It costs $370.

Open →

Chimney Cap Installation

A spark arrestor cap with mesh fine enough to stop embers, sized so the flue still breathes. We size it on the roof and then price it, by flue count and by metal.

Open →

Chimney Flashing Repair

Roof line metal that keeps rain off the framing, replaced in layers, with counter pieces cut into the brick itself.

Open →

Chimney Masonry Repair

Brick and mortar brought back to sound: flaking faces replaced, joints repointed, cracks from shaking closed and documented.

Open →

Chimney Rebuilds

Rebuilding above the roof to the height rule and current seismic practice, with a permit pulled where the city requires one.

Open →

Fireplace Cleaning

Firebox, damper and smoke shelf cleaned bare so an inspector can actually read the surfaces, with soot kept off the floor.

Open →

Gas Fireplace Cleaning

Gas units cleaned the way their own manual sets out, with the vent looked at and a CO reading taken before we leave.

Open →

Gas Fireplace Repair

Diagnosis on listed gas units with factory parts only, since a substitute part can void the listing the unit was approved under.

Open →

Fireplace Remodel

Remodels drawn up around clearance and hearth rules first, so the new look passes the city and the next inspector too.

Open →

Fireplace Inserts

Inserts fitted to the maker's listing with a full height liner, the clearance checks a city looks for, and a permit where required.

Open →

Wood Stove Repair

Wood stove repairs that keep the stove inside its listed clearances, from door seals to the connector pipe and floor protection.

Open →

Gas Logs

Log sets installed to their listing: vented sets with the damper held open as the manual requires, unvented sets only where allowed.

Open →

Chimney Seismic Retrofit

Bracing, strapping or a lighter top for a masonry chimney, with any permit filed and the work written up for your insurer.

Open →

Chimney Crown Repair

The top slab rebuilt to throw water off the brick, with a gap around the flue tile and an edge standing past the face.

Open →

Dryer Vent Cleaning

Lint cleared from the full duct run, with its length, material and outside hood compared against what the dryer maker allows.

Open →

Chimney Liner Installation

A listed liner sized to the appliance, needed when clay tile fails or when an insert or new stove goes in.

Open →

Chimney Leak Repair

Water traced to its entry point, then repaired, with the source written down so a seller or insurer has a clear record.

Open →

Chimney Waterproofing

A breathable repellent on brick that is already sound, applied after the crown, cap and flashing have passed.

Open →

Chimney Damper Repair

A damper that closes fully and opens fully, as needed when gas logs or a code inspection are part of the plan.

Open →

Chimney Chase Cover

Rusted pans on framed chimneys replaced with stainless covers sloped to shed water, fitted under the maker's listed cap.

Open →